Is it normal for a lithium ion battery to read with a very low voltage on a multimeter?












8












$begingroup$


I have a PS Vita and I suspect the battery is dead and needs replacing, as the Vita won't charge at all. But the issue could also be the charge circuit, as when plugging it in to charge the charging light doesn't even come on.



I've disassembled the Vita and removed the battery, which is a Sony SP65M 3.7V 2210 mAh Li-ion pack. It has 3 connectors: positive, temperature, and negative.



I suspect that the battery may be damaged from being left discharged for an extended period of time. I'm using a multimeter to measure the voltage across the + and - connectors, and I'm seeing a voltage of 20mV.



Does this mean the battery is dead, or am I jumping to conclusions? Is there any reason why I might see a voltage reading like this on a healthy battery?










share|improve this question









$endgroup$








  • 1




    $begingroup$
    20mV isn't okay there should be completeley drained or fully loaded by the charger itself...
    $endgroup$
    – sphericsf
    Jan 3 at 11:07












  • $begingroup$
    What is "PS Vita"? A car? A mobile phone? A drone? A household appliance? Something unspeakable?
    $endgroup$
    – Peter Mortensen
    Jan 3 at 20:54








  • 2




    $begingroup$
    Probably en.wikipedia.org/wiki/PlayStation_Vita
    $endgroup$
    – R..
    Jan 3 at 21:06
















8












$begingroup$


I have a PS Vita and I suspect the battery is dead and needs replacing, as the Vita won't charge at all. But the issue could also be the charge circuit, as when plugging it in to charge the charging light doesn't even come on.



I've disassembled the Vita and removed the battery, which is a Sony SP65M 3.7V 2210 mAh Li-ion pack. It has 3 connectors: positive, temperature, and negative.



I suspect that the battery may be damaged from being left discharged for an extended period of time. I'm using a multimeter to measure the voltage across the + and - connectors, and I'm seeing a voltage of 20mV.



Does this mean the battery is dead, or am I jumping to conclusions? Is there any reason why I might see a voltage reading like this on a healthy battery?










share|improve this question









$endgroup$








  • 1




    $begingroup$
    20mV isn't okay there should be completeley drained or fully loaded by the charger itself...
    $endgroup$
    – sphericsf
    Jan 3 at 11:07












  • $begingroup$
    What is "PS Vita"? A car? A mobile phone? A drone? A household appliance? Something unspeakable?
    $endgroup$
    – Peter Mortensen
    Jan 3 at 20:54








  • 2




    $begingroup$
    Probably en.wikipedia.org/wiki/PlayStation_Vita
    $endgroup$
    – R..
    Jan 3 at 21:06














8












8








8


1



$begingroup$


I have a PS Vita and I suspect the battery is dead and needs replacing, as the Vita won't charge at all. But the issue could also be the charge circuit, as when plugging it in to charge the charging light doesn't even come on.



I've disassembled the Vita and removed the battery, which is a Sony SP65M 3.7V 2210 mAh Li-ion pack. It has 3 connectors: positive, temperature, and negative.



I suspect that the battery may be damaged from being left discharged for an extended period of time. I'm using a multimeter to measure the voltage across the + and - connectors, and I'm seeing a voltage of 20mV.



Does this mean the battery is dead, or am I jumping to conclusions? Is there any reason why I might see a voltage reading like this on a healthy battery?










share|improve this question









$endgroup$




I have a PS Vita and I suspect the battery is dead and needs replacing, as the Vita won't charge at all. But the issue could also be the charge circuit, as when plugging it in to charge the charging light doesn't even come on.



I've disassembled the Vita and removed the battery, which is a Sony SP65M 3.7V 2210 mAh Li-ion pack. It has 3 connectors: positive, temperature, and negative.



I suspect that the battery may be damaged from being left discharged for an extended period of time. I'm using a multimeter to measure the voltage across the + and - connectors, and I'm seeing a voltage of 20mV.



Does this mean the battery is dead, or am I jumping to conclusions? Is there any reason why I might see a voltage reading like this on a healthy battery?







batteries lithium-ion voltage-measurement low-battery






share|improve this question













share|improve this question











share|improve this question




share|improve this question










asked Jan 3 at 10:29









Joshua WalshJoshua Walsh

1434




1434








  • 1




    $begingroup$
    20mV isn't okay there should be completeley drained or fully loaded by the charger itself...
    $endgroup$
    – sphericsf
    Jan 3 at 11:07












  • $begingroup$
    What is "PS Vita"? A car? A mobile phone? A drone? A household appliance? Something unspeakable?
    $endgroup$
    – Peter Mortensen
    Jan 3 at 20:54








  • 2




    $begingroup$
    Probably en.wikipedia.org/wiki/PlayStation_Vita
    $endgroup$
    – R..
    Jan 3 at 21:06














  • 1




    $begingroup$
    20mV isn't okay there should be completeley drained or fully loaded by the charger itself...
    $endgroup$
    – sphericsf
    Jan 3 at 11:07












  • $begingroup$
    What is "PS Vita"? A car? A mobile phone? A drone? A household appliance? Something unspeakable?
    $endgroup$
    – Peter Mortensen
    Jan 3 at 20:54








  • 2




    $begingroup$
    Probably en.wikipedia.org/wiki/PlayStation_Vita
    $endgroup$
    – R..
    Jan 3 at 21:06








1




1




$begingroup$
20mV isn't okay there should be completeley drained or fully loaded by the charger itself...
$endgroup$
– sphericsf
Jan 3 at 11:07






$begingroup$
20mV isn't okay there should be completeley drained or fully loaded by the charger itself...
$endgroup$
– sphericsf
Jan 3 at 11:07














$begingroup$
What is "PS Vita"? A car? A mobile phone? A drone? A household appliance? Something unspeakable?
$endgroup$
– Peter Mortensen
Jan 3 at 20:54






$begingroup$
What is "PS Vita"? A car? A mobile phone? A drone? A household appliance? Something unspeakable?
$endgroup$
– Peter Mortensen
Jan 3 at 20:54






2




2




$begingroup$
Probably en.wikipedia.org/wiki/PlayStation_Vita
$endgroup$
– R..
Jan 3 at 21:06




$begingroup$
Probably en.wikipedia.org/wiki/PlayStation_Vita
$endgroup$
– R..
Jan 3 at 21:06










1 Answer
1






active

oldest

votes


















16












$begingroup$

Almost any charging circuit for Lithium batteries has a low voltage protection built in. This will protect against charging dead batteries (which might overheat) and this also inhibits enabling the charger when no battery is present.



I have been faced with such a situation myself several times: the voltage of the battery (NiMH, LiIon, etc) was too low for the charger to work. I have succeeded in most cases to jump-start the system - in some cases the battery was really dead.



What I do is to charge the battery using a current limited voltage supply. I limit the current to less than 1/10th of the rated capacity of the battery (about 200mA in your case), and I charge about 10 minutes and monitor the voltage using a voltmeter. If the voltage is not high enough after 10 minutes, I'll continue to charge as long as the measured voltage at rest is increasing.
I'll set the voltage to something low to start (1V) and limit the current as indicated.



Once the voltage is high enough, I put it back in the original system and I check that it is charging. If not, I may continue to charge it outside the system until the voltage is higher. For Lithium batteries, 2.5V should be sufficient for the original charger to be happy (which is of course a guess), usually it is lower.



I also have a charger which will charge any type of battery according to the charger settings. This allows me to charge the battery in a controlled manner. It also has a low battery safety protection so I still need to pre-charge the empty battery before. But it starts charging at a pretty low voltage and it clearly reports the charging error on its LCD which is convenient. Such a charger allows you to charge a battery completely before putting it back into the original system.



As an example with some "side effects" that show that you must be patient and/or measure:



With a Samsung Galaxy Tab3 that I fixed this way, I noticed that it required:




  1. The "official charger" (AC to USB converter) [Not sure, but I had this impression];

  2. Some extra time before it showed that it was charging.
    I initially thought that it did not work, but the voltage it was presenting to the battery was higher than at rest. It just required extra charge before the screen lit up - charge that the internal charger was able to build up.


WARNINGS



You must monitor the charging while you are doing this. If the battery heats up or is building up gas internally: stop trying to recover it. If there is a risk that you forget monitoring it: use a timed wall plug, set multiple alarms (phone, PC, ...) to make sure that you check on your system.
When possible I put the battery in a box and I put a transparent lid on it. I did not have any problem yet, but in case it leaks or "explodes", there is at least some protection. If it does leak for any reason -protect yourself from the chemicals and dispose of the battery in a controlled manner.



DO NOT DO THIS WITH BATTERIES THAT ARE OBVIOUSLY IN BAD SHAPE (leaking, built-up gas, damaged)



I am talking about small batteries - that is where I have experience.



If the battery voltage is not increasing rapidly, the battery is dead. Which means it should go from close to 0V to 0.5/0.8V in just a few minutes (measured when it is not charging).



I recommend not doing this if you do not know what current limiting is or if you do not have any means to achieve and verify the actual current limit



And of course, this is entirely at your risk! Be carefull and stop when in doubt - the battery or anything else should not heat, leak or smoke. The slightest sign of that: STOP the process!






share|improve this answer











$endgroup$













  • $begingroup$
    With an automotive battery, you can do something similar to this by putting a charged battery in parallel and hooking them up to a charger. The parallel battery fools the charger, and the depleted battery accept the juice. I use this method to resuscitate AGM batteries. Would it work for lithium chemistry, or would that be too much?
    $endgroup$
    – YetAnotherRandomUser
    Jan 3 at 14:15








  • 5




    $begingroup$
    @YetAnotherRandomUser This is a very dangerous way to proceed for both automotive and lithium batteries, which can deliver very high currents when fully charged.
    $endgroup$
    – Finbarr
    Jan 3 at 15:05










  • $begingroup$
    @Finbarr Needs more bold. What YetAnotherRandomUser suggests is dangerous.
    $endgroup$
    – wizzwizz4
    Jan 3 at 17:12






  • 2




    $begingroup$
    Yes what @YetAnotherRandomUser suggests is VERY DANGEROUS because the extra battery will charge the depleted battery at uncontrolled currents. What I suggest is to keep the current low enough and to make sure that charging is effective and abandon when the voltage does not increase.
    $endgroup$
    – le_top
    Jan 3 at 21:02












  • $begingroup$
    @le_top Thanks for the advice. I don't have a current limited power supply, so I'll probably just buy a replacement battery. I was mostly interested in understanding if the 20mA reading definitely represents a discharged battery, or if my measurement was somehow misleading. Based on your answer I'm now confident that it does, thank you.
    $endgroup$
    – Joshua Walsh
    Jan 4 at 0:17












Your Answer





StackExchange.ifUsing("editor", function () {
return StackExchange.using("mathjaxEditing", function () {
StackExchange.MarkdownEditor.creationCallbacks.add(function (editor, postfix) {
StackExchange.mathjaxEditing.prepareWmdForMathJax(editor, postfix, [["\$", "\$"]]);
});
});
}, "mathjax-editing");

StackExchange.ifUsing("editor", function () {
return StackExchange.using("schematics", function () {
StackExchange.schematics.init();
});
}, "cicuitlab");

StackExchange.ready(function() {
var channelOptions = {
tags: "".split(" "),
id: "135"
};
initTagRenderer("".split(" "), "".split(" "), channelOptions);

StackExchange.using("externalEditor", function() {
// Have to fire editor after snippets, if snippets enabled
if (StackExchange.settings.snippets.snippetsEnabled) {
StackExchange.using("snippets", function() {
createEditor();
});
}
else {
createEditor();
}
});

function createEditor() {
StackExchange.prepareEditor({
heartbeatType: 'answer',
autoActivateHeartbeat: false,
convertImagesToLinks: false,
noModals: true,
showLowRepImageUploadWarning: true,
reputationToPostImages: null,
bindNavPrevention: true,
postfix: "",
imageUploader: {
brandingHtml: "Powered by u003ca class="icon-imgur-white" href="https://imgur.com/"u003eu003c/au003e",
contentPolicyHtml: "User contributions licensed under u003ca href="https://creativecommons.org/licenses/by-sa/3.0/"u003ecc by-sa 3.0 with attribution requiredu003c/au003e u003ca href="https://stackoverflow.com/legal/content-policy"u003e(content policy)u003c/au003e",
allowUrls: true
},
onDemand: true,
discardSelector: ".discard-answer"
,immediatelyShowMarkdownHelp:true
});


}
});














draft saved

draft discarded


















StackExchange.ready(
function () {
StackExchange.openid.initPostLogin('.new-post-login', 'https%3a%2f%2felectronics.stackexchange.com%2fquestions%2f415011%2fis-it-normal-for-a-lithium-ion-battery-to-read-with-a-very-low-voltage-on-a-mult%23new-answer', 'question_page');
}
);

Post as a guest















Required, but never shown

























1 Answer
1






active

oldest

votes








1 Answer
1






active

oldest

votes









active

oldest

votes






active

oldest

votes









16












$begingroup$

Almost any charging circuit for Lithium batteries has a low voltage protection built in. This will protect against charging dead batteries (which might overheat) and this also inhibits enabling the charger when no battery is present.



I have been faced with such a situation myself several times: the voltage of the battery (NiMH, LiIon, etc) was too low for the charger to work. I have succeeded in most cases to jump-start the system - in some cases the battery was really dead.



What I do is to charge the battery using a current limited voltage supply. I limit the current to less than 1/10th of the rated capacity of the battery (about 200mA in your case), and I charge about 10 minutes and monitor the voltage using a voltmeter. If the voltage is not high enough after 10 minutes, I'll continue to charge as long as the measured voltage at rest is increasing.
I'll set the voltage to something low to start (1V) and limit the current as indicated.



Once the voltage is high enough, I put it back in the original system and I check that it is charging. If not, I may continue to charge it outside the system until the voltage is higher. For Lithium batteries, 2.5V should be sufficient for the original charger to be happy (which is of course a guess), usually it is lower.



I also have a charger which will charge any type of battery according to the charger settings. This allows me to charge the battery in a controlled manner. It also has a low battery safety protection so I still need to pre-charge the empty battery before. But it starts charging at a pretty low voltage and it clearly reports the charging error on its LCD which is convenient. Such a charger allows you to charge a battery completely before putting it back into the original system.



As an example with some "side effects" that show that you must be patient and/or measure:



With a Samsung Galaxy Tab3 that I fixed this way, I noticed that it required:




  1. The "official charger" (AC to USB converter) [Not sure, but I had this impression];

  2. Some extra time before it showed that it was charging.
    I initially thought that it did not work, but the voltage it was presenting to the battery was higher than at rest. It just required extra charge before the screen lit up - charge that the internal charger was able to build up.


WARNINGS



You must monitor the charging while you are doing this. If the battery heats up or is building up gas internally: stop trying to recover it. If there is a risk that you forget monitoring it: use a timed wall plug, set multiple alarms (phone, PC, ...) to make sure that you check on your system.
When possible I put the battery in a box and I put a transparent lid on it. I did not have any problem yet, but in case it leaks or "explodes", there is at least some protection. If it does leak for any reason -protect yourself from the chemicals and dispose of the battery in a controlled manner.



DO NOT DO THIS WITH BATTERIES THAT ARE OBVIOUSLY IN BAD SHAPE (leaking, built-up gas, damaged)



I am talking about small batteries - that is where I have experience.



If the battery voltage is not increasing rapidly, the battery is dead. Which means it should go from close to 0V to 0.5/0.8V in just a few minutes (measured when it is not charging).



I recommend not doing this if you do not know what current limiting is or if you do not have any means to achieve and verify the actual current limit



And of course, this is entirely at your risk! Be carefull and stop when in doubt - the battery or anything else should not heat, leak or smoke. The slightest sign of that: STOP the process!






share|improve this answer











$endgroup$













  • $begingroup$
    With an automotive battery, you can do something similar to this by putting a charged battery in parallel and hooking them up to a charger. The parallel battery fools the charger, and the depleted battery accept the juice. I use this method to resuscitate AGM batteries. Would it work for lithium chemistry, or would that be too much?
    $endgroup$
    – YetAnotherRandomUser
    Jan 3 at 14:15








  • 5




    $begingroup$
    @YetAnotherRandomUser This is a very dangerous way to proceed for both automotive and lithium batteries, which can deliver very high currents when fully charged.
    $endgroup$
    – Finbarr
    Jan 3 at 15:05










  • $begingroup$
    @Finbarr Needs more bold. What YetAnotherRandomUser suggests is dangerous.
    $endgroup$
    – wizzwizz4
    Jan 3 at 17:12






  • 2




    $begingroup$
    Yes what @YetAnotherRandomUser suggests is VERY DANGEROUS because the extra battery will charge the depleted battery at uncontrolled currents. What I suggest is to keep the current low enough and to make sure that charging is effective and abandon when the voltage does not increase.
    $endgroup$
    – le_top
    Jan 3 at 21:02












  • $begingroup$
    @le_top Thanks for the advice. I don't have a current limited power supply, so I'll probably just buy a replacement battery. I was mostly interested in understanding if the 20mA reading definitely represents a discharged battery, or if my measurement was somehow misleading. Based on your answer I'm now confident that it does, thank you.
    $endgroup$
    – Joshua Walsh
    Jan 4 at 0:17
















16












$begingroup$

Almost any charging circuit for Lithium batteries has a low voltage protection built in. This will protect against charging dead batteries (which might overheat) and this also inhibits enabling the charger when no battery is present.



I have been faced with such a situation myself several times: the voltage of the battery (NiMH, LiIon, etc) was too low for the charger to work. I have succeeded in most cases to jump-start the system - in some cases the battery was really dead.



What I do is to charge the battery using a current limited voltage supply. I limit the current to less than 1/10th of the rated capacity of the battery (about 200mA in your case), and I charge about 10 minutes and monitor the voltage using a voltmeter. If the voltage is not high enough after 10 minutes, I'll continue to charge as long as the measured voltage at rest is increasing.
I'll set the voltage to something low to start (1V) and limit the current as indicated.



Once the voltage is high enough, I put it back in the original system and I check that it is charging. If not, I may continue to charge it outside the system until the voltage is higher. For Lithium batteries, 2.5V should be sufficient for the original charger to be happy (which is of course a guess), usually it is lower.



I also have a charger which will charge any type of battery according to the charger settings. This allows me to charge the battery in a controlled manner. It also has a low battery safety protection so I still need to pre-charge the empty battery before. But it starts charging at a pretty low voltage and it clearly reports the charging error on its LCD which is convenient. Such a charger allows you to charge a battery completely before putting it back into the original system.



As an example with some "side effects" that show that you must be patient and/or measure:



With a Samsung Galaxy Tab3 that I fixed this way, I noticed that it required:




  1. The "official charger" (AC to USB converter) [Not sure, but I had this impression];

  2. Some extra time before it showed that it was charging.
    I initially thought that it did not work, but the voltage it was presenting to the battery was higher than at rest. It just required extra charge before the screen lit up - charge that the internal charger was able to build up.


WARNINGS



You must monitor the charging while you are doing this. If the battery heats up or is building up gas internally: stop trying to recover it. If there is a risk that you forget monitoring it: use a timed wall plug, set multiple alarms (phone, PC, ...) to make sure that you check on your system.
When possible I put the battery in a box and I put a transparent lid on it. I did not have any problem yet, but in case it leaks or "explodes", there is at least some protection. If it does leak for any reason -protect yourself from the chemicals and dispose of the battery in a controlled manner.



DO NOT DO THIS WITH BATTERIES THAT ARE OBVIOUSLY IN BAD SHAPE (leaking, built-up gas, damaged)



I am talking about small batteries - that is where I have experience.



If the battery voltage is not increasing rapidly, the battery is dead. Which means it should go from close to 0V to 0.5/0.8V in just a few minutes (measured when it is not charging).



I recommend not doing this if you do not know what current limiting is or if you do not have any means to achieve and verify the actual current limit



And of course, this is entirely at your risk! Be carefull and stop when in doubt - the battery or anything else should not heat, leak or smoke. The slightest sign of that: STOP the process!






share|improve this answer











$endgroup$













  • $begingroup$
    With an automotive battery, you can do something similar to this by putting a charged battery in parallel and hooking them up to a charger. The parallel battery fools the charger, and the depleted battery accept the juice. I use this method to resuscitate AGM batteries. Would it work for lithium chemistry, or would that be too much?
    $endgroup$
    – YetAnotherRandomUser
    Jan 3 at 14:15








  • 5




    $begingroup$
    @YetAnotherRandomUser This is a very dangerous way to proceed for both automotive and lithium batteries, which can deliver very high currents when fully charged.
    $endgroup$
    – Finbarr
    Jan 3 at 15:05










  • $begingroup$
    @Finbarr Needs more bold. What YetAnotherRandomUser suggests is dangerous.
    $endgroup$
    – wizzwizz4
    Jan 3 at 17:12






  • 2




    $begingroup$
    Yes what @YetAnotherRandomUser suggests is VERY DANGEROUS because the extra battery will charge the depleted battery at uncontrolled currents. What I suggest is to keep the current low enough and to make sure that charging is effective and abandon when the voltage does not increase.
    $endgroup$
    – le_top
    Jan 3 at 21:02












  • $begingroup$
    @le_top Thanks for the advice. I don't have a current limited power supply, so I'll probably just buy a replacement battery. I was mostly interested in understanding if the 20mA reading definitely represents a discharged battery, or if my measurement was somehow misleading. Based on your answer I'm now confident that it does, thank you.
    $endgroup$
    – Joshua Walsh
    Jan 4 at 0:17














16












16








16





$begingroup$

Almost any charging circuit for Lithium batteries has a low voltage protection built in. This will protect against charging dead batteries (which might overheat) and this also inhibits enabling the charger when no battery is present.



I have been faced with such a situation myself several times: the voltage of the battery (NiMH, LiIon, etc) was too low for the charger to work. I have succeeded in most cases to jump-start the system - in some cases the battery was really dead.



What I do is to charge the battery using a current limited voltage supply. I limit the current to less than 1/10th of the rated capacity of the battery (about 200mA in your case), and I charge about 10 minutes and monitor the voltage using a voltmeter. If the voltage is not high enough after 10 minutes, I'll continue to charge as long as the measured voltage at rest is increasing.
I'll set the voltage to something low to start (1V) and limit the current as indicated.



Once the voltage is high enough, I put it back in the original system and I check that it is charging. If not, I may continue to charge it outside the system until the voltage is higher. For Lithium batteries, 2.5V should be sufficient for the original charger to be happy (which is of course a guess), usually it is lower.



I also have a charger which will charge any type of battery according to the charger settings. This allows me to charge the battery in a controlled manner. It also has a low battery safety protection so I still need to pre-charge the empty battery before. But it starts charging at a pretty low voltage and it clearly reports the charging error on its LCD which is convenient. Such a charger allows you to charge a battery completely before putting it back into the original system.



As an example with some "side effects" that show that you must be patient and/or measure:



With a Samsung Galaxy Tab3 that I fixed this way, I noticed that it required:




  1. The "official charger" (AC to USB converter) [Not sure, but I had this impression];

  2. Some extra time before it showed that it was charging.
    I initially thought that it did not work, but the voltage it was presenting to the battery was higher than at rest. It just required extra charge before the screen lit up - charge that the internal charger was able to build up.


WARNINGS



You must monitor the charging while you are doing this. If the battery heats up or is building up gas internally: stop trying to recover it. If there is a risk that you forget monitoring it: use a timed wall plug, set multiple alarms (phone, PC, ...) to make sure that you check on your system.
When possible I put the battery in a box and I put a transparent lid on it. I did not have any problem yet, but in case it leaks or "explodes", there is at least some protection. If it does leak for any reason -protect yourself from the chemicals and dispose of the battery in a controlled manner.



DO NOT DO THIS WITH BATTERIES THAT ARE OBVIOUSLY IN BAD SHAPE (leaking, built-up gas, damaged)



I am talking about small batteries - that is where I have experience.



If the battery voltage is not increasing rapidly, the battery is dead. Which means it should go from close to 0V to 0.5/0.8V in just a few minutes (measured when it is not charging).



I recommend not doing this if you do not know what current limiting is or if you do not have any means to achieve and verify the actual current limit



And of course, this is entirely at your risk! Be carefull and stop when in doubt - the battery or anything else should not heat, leak or smoke. The slightest sign of that: STOP the process!






share|improve this answer











$endgroup$



Almost any charging circuit for Lithium batteries has a low voltage protection built in. This will protect against charging dead batteries (which might overheat) and this also inhibits enabling the charger when no battery is present.



I have been faced with such a situation myself several times: the voltage of the battery (NiMH, LiIon, etc) was too low for the charger to work. I have succeeded in most cases to jump-start the system - in some cases the battery was really dead.



What I do is to charge the battery using a current limited voltage supply. I limit the current to less than 1/10th of the rated capacity of the battery (about 200mA in your case), and I charge about 10 minutes and monitor the voltage using a voltmeter. If the voltage is not high enough after 10 minutes, I'll continue to charge as long as the measured voltage at rest is increasing.
I'll set the voltage to something low to start (1V) and limit the current as indicated.



Once the voltage is high enough, I put it back in the original system and I check that it is charging. If not, I may continue to charge it outside the system until the voltage is higher. For Lithium batteries, 2.5V should be sufficient for the original charger to be happy (which is of course a guess), usually it is lower.



I also have a charger which will charge any type of battery according to the charger settings. This allows me to charge the battery in a controlled manner. It also has a low battery safety protection so I still need to pre-charge the empty battery before. But it starts charging at a pretty low voltage and it clearly reports the charging error on its LCD which is convenient. Such a charger allows you to charge a battery completely before putting it back into the original system.



As an example with some "side effects" that show that you must be patient and/or measure:



With a Samsung Galaxy Tab3 that I fixed this way, I noticed that it required:




  1. The "official charger" (AC to USB converter) [Not sure, but I had this impression];

  2. Some extra time before it showed that it was charging.
    I initially thought that it did not work, but the voltage it was presenting to the battery was higher than at rest. It just required extra charge before the screen lit up - charge that the internal charger was able to build up.


WARNINGS



You must monitor the charging while you are doing this. If the battery heats up or is building up gas internally: stop trying to recover it. If there is a risk that you forget monitoring it: use a timed wall plug, set multiple alarms (phone, PC, ...) to make sure that you check on your system.
When possible I put the battery in a box and I put a transparent lid on it. I did not have any problem yet, but in case it leaks or "explodes", there is at least some protection. If it does leak for any reason -protect yourself from the chemicals and dispose of the battery in a controlled manner.



DO NOT DO THIS WITH BATTERIES THAT ARE OBVIOUSLY IN BAD SHAPE (leaking, built-up gas, damaged)



I am talking about small batteries - that is where I have experience.



If the battery voltage is not increasing rapidly, the battery is dead. Which means it should go from close to 0V to 0.5/0.8V in just a few minutes (measured when it is not charging).



I recommend not doing this if you do not know what current limiting is or if you do not have any means to achieve and verify the actual current limit



And of course, this is entirely at your risk! Be carefull and stop when in doubt - the battery or anything else should not heat, leak or smoke. The slightest sign of that: STOP the process!







share|improve this answer














share|improve this answer



share|improve this answer








edited Jan 10 at 9:59









winny

4,85641933




4,85641933










answered Jan 3 at 12:33









le_tople_top

1,167312




1,167312












  • $begingroup$
    With an automotive battery, you can do something similar to this by putting a charged battery in parallel and hooking them up to a charger. The parallel battery fools the charger, and the depleted battery accept the juice. I use this method to resuscitate AGM batteries. Would it work for lithium chemistry, or would that be too much?
    $endgroup$
    – YetAnotherRandomUser
    Jan 3 at 14:15








  • 5




    $begingroup$
    @YetAnotherRandomUser This is a very dangerous way to proceed for both automotive and lithium batteries, which can deliver very high currents when fully charged.
    $endgroup$
    – Finbarr
    Jan 3 at 15:05










  • $begingroup$
    @Finbarr Needs more bold. What YetAnotherRandomUser suggests is dangerous.
    $endgroup$
    – wizzwizz4
    Jan 3 at 17:12






  • 2




    $begingroup$
    Yes what @YetAnotherRandomUser suggests is VERY DANGEROUS because the extra battery will charge the depleted battery at uncontrolled currents. What I suggest is to keep the current low enough and to make sure that charging is effective and abandon when the voltage does not increase.
    $endgroup$
    – le_top
    Jan 3 at 21:02












  • $begingroup$
    @le_top Thanks for the advice. I don't have a current limited power supply, so I'll probably just buy a replacement battery. I was mostly interested in understanding if the 20mA reading definitely represents a discharged battery, or if my measurement was somehow misleading. Based on your answer I'm now confident that it does, thank you.
    $endgroup$
    – Joshua Walsh
    Jan 4 at 0:17


















  • $begingroup$
    With an automotive battery, you can do something similar to this by putting a charged battery in parallel and hooking them up to a charger. The parallel battery fools the charger, and the depleted battery accept the juice. I use this method to resuscitate AGM batteries. Would it work for lithium chemistry, or would that be too much?
    $endgroup$
    – YetAnotherRandomUser
    Jan 3 at 14:15








  • 5




    $begingroup$
    @YetAnotherRandomUser This is a very dangerous way to proceed for both automotive and lithium batteries, which can deliver very high currents when fully charged.
    $endgroup$
    – Finbarr
    Jan 3 at 15:05










  • $begingroup$
    @Finbarr Needs more bold. What YetAnotherRandomUser suggests is dangerous.
    $endgroup$
    – wizzwizz4
    Jan 3 at 17:12






  • 2




    $begingroup$
    Yes what @YetAnotherRandomUser suggests is VERY DANGEROUS because the extra battery will charge the depleted battery at uncontrolled currents. What I suggest is to keep the current low enough and to make sure that charging is effective and abandon when the voltage does not increase.
    $endgroup$
    – le_top
    Jan 3 at 21:02












  • $begingroup$
    @le_top Thanks for the advice. I don't have a current limited power supply, so I'll probably just buy a replacement battery. I was mostly interested in understanding if the 20mA reading definitely represents a discharged battery, or if my measurement was somehow misleading. Based on your answer I'm now confident that it does, thank you.
    $endgroup$
    – Joshua Walsh
    Jan 4 at 0:17
















$begingroup$
With an automotive battery, you can do something similar to this by putting a charged battery in parallel and hooking them up to a charger. The parallel battery fools the charger, and the depleted battery accept the juice. I use this method to resuscitate AGM batteries. Would it work for lithium chemistry, or would that be too much?
$endgroup$
– YetAnotherRandomUser
Jan 3 at 14:15






$begingroup$
With an automotive battery, you can do something similar to this by putting a charged battery in parallel and hooking them up to a charger. The parallel battery fools the charger, and the depleted battery accept the juice. I use this method to resuscitate AGM batteries. Would it work for lithium chemistry, or would that be too much?
$endgroup$
– YetAnotherRandomUser
Jan 3 at 14:15






5




5




$begingroup$
@YetAnotherRandomUser This is a very dangerous way to proceed for both automotive and lithium batteries, which can deliver very high currents when fully charged.
$endgroup$
– Finbarr
Jan 3 at 15:05




$begingroup$
@YetAnotherRandomUser This is a very dangerous way to proceed for both automotive and lithium batteries, which can deliver very high currents when fully charged.
$endgroup$
– Finbarr
Jan 3 at 15:05












$begingroup$
@Finbarr Needs more bold. What YetAnotherRandomUser suggests is dangerous.
$endgroup$
– wizzwizz4
Jan 3 at 17:12




$begingroup$
@Finbarr Needs more bold. What YetAnotherRandomUser suggests is dangerous.
$endgroup$
– wizzwizz4
Jan 3 at 17:12




2




2




$begingroup$
Yes what @YetAnotherRandomUser suggests is VERY DANGEROUS because the extra battery will charge the depleted battery at uncontrolled currents. What I suggest is to keep the current low enough and to make sure that charging is effective and abandon when the voltage does not increase.
$endgroup$
– le_top
Jan 3 at 21:02






$begingroup$
Yes what @YetAnotherRandomUser suggests is VERY DANGEROUS because the extra battery will charge the depleted battery at uncontrolled currents. What I suggest is to keep the current low enough and to make sure that charging is effective and abandon when the voltage does not increase.
$endgroup$
– le_top
Jan 3 at 21:02














$begingroup$
@le_top Thanks for the advice. I don't have a current limited power supply, so I'll probably just buy a replacement battery. I was mostly interested in understanding if the 20mA reading definitely represents a discharged battery, or if my measurement was somehow misleading. Based on your answer I'm now confident that it does, thank you.
$endgroup$
– Joshua Walsh
Jan 4 at 0:17




$begingroup$
@le_top Thanks for the advice. I don't have a current limited power supply, so I'll probably just buy a replacement battery. I was mostly interested in understanding if the 20mA reading definitely represents a discharged battery, or if my measurement was somehow misleading. Based on your answer I'm now confident that it does, thank you.
$endgroup$
– Joshua Walsh
Jan 4 at 0:17


















draft saved

draft discarded




















































Thanks for contributing an answer to Electrical Engineering Stack Exchange!


  • Please be sure to answer the question. Provide details and share your research!

But avoid



  • Asking for help, clarification, or responding to other answers.

  • Making statements based on opinion; back them up with references or personal experience.


Use MathJax to format equations. MathJax reference.


To learn more, see our tips on writing great answers.




draft saved


draft discarded














StackExchange.ready(
function () {
StackExchange.openid.initPostLogin('.new-post-login', 'https%3a%2f%2felectronics.stackexchange.com%2fquestions%2f415011%2fis-it-normal-for-a-lithium-ion-battery-to-read-with-a-very-low-voltage-on-a-mult%23new-answer', 'question_page');
}
);

Post as a guest















Required, but never shown





















































Required, but never shown














Required, but never shown












Required, but never shown







Required, but never shown

































Required, but never shown














Required, but never shown












Required, but never shown







Required, but never shown







Popular posts from this blog

Wiesbaden

Marschland

Dieringhausen